DATA SUMMARIES
TEMPERATURE RISE (Current Carrying Capacity, CCC):
1) High quality thermocouples whose temperature slopes track one another were used for temperature
monitoring.
2) The thermocouples were placed at a location to sense the maximum temperature generated during testing.
3) Temperature readings recorded are those for which three successive readings, 15 minutes apart, differ less
than 1° C (computer controlled data acquisition).
4) Adjacent contacts were powered:
a. Six adjacent signal contacts powered
b. Ground System Powered
TC0430--0495
EEDP-16-6.00-DV1-DV2-2
6 Adjacent SignalContacts Powered
Measured on cable
2.82.8
2.22.2
2.42.4
1.91.9
2.02.0
1.61.6
1.21.2
0.90.9
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
20 30 40 50 60 70 80 90
Ambient
Temperature, ° C
Maximum
Current, Amp
Base Curve
Derated 20 %
RT Peak Amp
RT Derated Amp
Measured Current
40 ° C
40 ° C Peak Amp
40 ° C Derated Amp
50 ° C
50 ° C Peak Amp
50 ° C Derated Amp
Limit
70 ° C Peak Amp
70 ° C Derated Amp
70 ° C
Room Temp
80° C
Limit
Useful Range
Room Temp= 23.3 C